Universal stationary sensor type UCS-2
UCS-2: Reliable Sensor for Industry and Mining
The UCS-2 is a universal stationary sensor designed for safe use in explosive zones. It combines precise measurement, easy operation, and high durability. This is the second generation of the sensor — improved based on feedback from users of the first version.
What It Measures
- Explosive and toxic gases: CH₄, CO, H₂S, CO₂
- Oxygen (O₂)
- Atmospheric parameters: temperature, humidity, pressure, and differential pressure.
Each device contains one built-in measurement sensor – for gases (CH₄, CO, H₂S, CO₂), oxygen (O₂), and differential pressure, each parameter is measured by a separate sensor, while temperature, humidity, and atmospheric pressure are measured by a single integrated sensor.
How It Works and Communicates
- Data transmission via RS485 or telemetry line
- Two RS485 interfaces – sensors can be connected in parallel or in a repeater chain, making installation and system expansion easier
- Full integration with ROOTTEL and SEVITEL telemetry systems (e.g., SMP)
- Optional connection of external sensors via RS485 or analog inputs
Functions and Operation
- Instant status indication – color LEDs show normal, warning, or alarm state at a glance
- Clear LCD display – shows live readings and device status for easy setup and diagnostics
- Flexible alarm thresholds – can be set locally or remotely from a central system
- Easy calibration – quick zeroing and adjustment using a keypad
Outputs and Automation
- Up to 2 opto-isolated relay outputs
- Analog outputs: 0.4–2.0 V or 4–20 mA (with intrinsically safe power supply)
- Input ports for external devices (analog or contact type)
- Standalone mode – can locally control fans, pumps, or alarms
Durability and Safety
- ATEX certified (JSHP 24ATEX0046) – approved for explosive areas
- IP65 housing – dust- and moisture-resistant
- Operating range: –20 °C to +40 °C, humidity up to 96 % (no condensation)
- Optional backup battery – up to 6 h of emergency power (electrochemical sensors) or 2 h (others)
- Compact and lightweight design (0.8–1.2 kg), installable in any position
Why Choose UCS-2
- Proven solution – second-generation sensor built on real-world experience
- Flexible integration – works with leading telemetry systems (e.g., SMP)
- Fast response – instant LED and system alarm signaling
- Practical reliability – simple use, rugged build, predictable maintenance (monthly calibration, filter replacement)
The Result
With UCS-2, you gain stable, continuous monitoring of the atmosphere and easy integration into plant systems. It combines precision measurement with low maintenance needs, ensuring consistent performance and peace of mind in daily operations.
Measurement Ranges and Measurement Errors
Sensor Type Parameter Measurement Range Measurement Error IR Optical Sensors CH₄ 0..5 % ±0.1% CH₄ 0..100 % ±2% CO₂ 0..5 % ±0.1% Catalytic Sensor CH₄ 0..5 % ±0.1% Conductometric Sensor CH₄ 5..100 % ±2% Electrochemical Sensors H₂S 0..200 ppm ±3 ppm CO 0..200 ppm ±2 ppm (<100 ppm) ±5 ppm (>100 ppm) CO 0..1000 ppm ±25 ppm (>200 ppm) CO 0..2000 ppm ±40 ppm (>800 ppm) O₂ 0..25 % ±3% Other Sensors Temperature -20..+60 °C ±1°C Humidity 0..98 % rH ±3% Atmospheric Pressure 85..130 kPa ±1% Differential Pressure -250..+250 Pa ±0.25% FS -500..+500 Pa ±0.25% FS -1250..+1250 Pa ±0.25% FS -2500..+2500 Pa ±0.25% FS External Temperature Probe DS Temperature -20..+80 °C ±0.5°C Quantity up to 8 pcs. – Technical Specification
Parameter Value Power Supply from telemetry line 60V/50mA from intrinsically safe power supply 12..15V Power Autonomy up to 6h for electrochemical sensors up to 2h for other sensors User Interface graphical LCD display 3-color LED keyboard with 4 buttons Ready Time 60s from connection Response Time (t90)
Sensor Response Time H₂S, CO < 40s O₂ < 15s IR < 30s Pressure < 1s Temperature < 60s Humidity < 30s CH₄ type EKP-1/NW < 8s CH₄ type SG-1/NW < 5s Salinity, pH < 60s Transmission and Interfaces
Parameter Specification Data Transmission 2 × RS485 modem transmission to dispatcher telemetry systems (e.g. SMP) Outputs (optional) 2 optically isolated contact outputs Umax = 60V, Imax = 100mA, Pmax = 0.45W, 2 analog outputs 0.4..2.0V or 1 output 0.4..2.0V and 1 output 4..20mA (4..20mA only when powered by power supply) Inputs (optional) 2 contact inputs with line status control 2 analog inputs 0.4..2.0V Construction and Environmental Parameters
Parameter Value Operating Conditions -20..+40 °C, 0..96 % rH without condensation Weight 0.8 kg or 1.2 kg Dimensions approx. 170 × 100 × 65 mm (single-box version) approx. 170 × 175 × 65 mm (double-box version) Protection Rating IP 65